LUXON β Controller
Overview
The LUXONβ controller is a versatile controller designed for breathing air compressors.
Can clearly display: temperature, pressure, equipment operation, failure signal, maintenance period and other data.
Specification
Triangle start
Automatic on/off
Manual on/off switch
Timer (machine running time)
Maintenance reminder
Interstage pressure
Oil pressure failure alarm
Oil temperature fault alarm
Final temperature detection
Oil level alarm
Motor overload protection
Phase sequence protection (missing phase, phase sequence)
With device initialization
Parameters
Oil temperature regulation
Type number | LUXON β controller single phase | Remark |
Booking Number | Please contact our sales | |
Pressure range(Bar) | 0-350 | Default 200Bar |
temperature regulation(℃) | 1-55 | Default 45℃ |
1-100 | Default 45℃ | |
High oil pressure range(Bar) | 0-25 | Default 5Bar |
Low oil pressure range(Bar) | 0-5 | Default 0Bar(High oil pressure is greater than low oil pressure) |
temperature regulation
Type Numbe | LUXON β controller three phase | Remark |
Booking Number | Please contact our sales | |
Pressure range (Bar) | 0-350 | Default 200Bar |
1-55 | Default 45℃ | |
Oil temperature regulation(℃) | 1-100 | Default 45℃ |
High oil pressure range(Bar) | 0-25 | Default 5Bar |
Low oil pressure range(Bar) | 0-5 | Default 0Bar(High oil pressure is greater than low oil pressure) |